|
|
|
|
|
|
|
|
|
|
|
Plastic (snap-in) for type BR 1 in space. May also be used with 400 and 600 A load centers.
|
For grounding copper or aluminum terminals in a GE load center. Offers 4 small holes for 14 to 8 AWG copper or 12 to 8 AWG aluminum terminals and 3 large holes for 14 to 4 AWG copper or 12 to 4 AWG aluminum terminals. UL listed and ANSI certified. 6-7/8 in H x 2-7/8 in W x 1/2 in depth, 0.105 lb.
|
GE Filler Plate Kit, 6-7/8 in Length, 2-7/8 in Width, 3/4 in Height
|
|
|
|
|
|
|
|
|
|
|
|
|
For use with wire range 6-2/0. Can be mounted on any neutral or ground position by simply removing the termination screw. UL listed. 2-7/8 in H x 3/4 in W x 6-7/8 in D, 0.07 lb.
|
Siemens Filler Plate, Plastic, Black, 1 in Width, 3 in Height
|
Used in load centers, CSED devices and NQOD and NF panel boards. Each terminal accepts one #14 - #4 copper wire or one #12 - #4 aluminum wire, two #14 - #12 copper wire or two #12 - #10 aluminum wire. ANSI certified and UL listed.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Used in load centers, CSED devices and NQOD and NF panel boards. Each terminal accepts one #14 - #4 copper wire or one #12 - #4 aluminum wire, two #14 - #12 copper wire or two #12 - #10 aluminum wire. ANSI certified and UL listed.
|
Fills opening in covers if twist out is removed in error. QOFPCP are used only in QO load centers, filling the spaces where no circuit is attached. CHOMFPCP are for use only in Homeline load centers. UL listed and ANSI Certified.
|
|
|
|
|
|
|
|
|
|
|
|
|
Used for additional grounding as required by local code. Compatible with most load center enclosures. Fits solid or stranded 4 - 14 copper wire and 10 - 12 aluminum wire. Includes mounting screws. UL listed and ANSI certified. 11 in H x 3-1/2 in W x 1/2 in D, 0.304 lb.
|
Made for QO load centers. Field installed for number 12 to 2 Al or number 14 to 4 Cu wire. QO accessories can only be used with QO load centers.
|
Used in load centers, CSED devices and NQOD and NF panel boards. Each terminal accepts one #14 - #4 copper wire or one #12 - #4 aluminum wire, two #14 - #12 copper wire or two #12 - #10 aluminum wire. ANSI certified and UL listed.
|
|
|
|
|
|
|
|
|
|
|
|
|
Siemens ECLX Ground Bar Kit, 11 Terminals, (3) 14 to 1/0 AWG Large Opening Copper/Aluminum, (8) 14 to 6 AWG Small Opening Wire, Aluminum/Copper, 3-1/2 in Length, 5.1 in Width, 5.1 in Height, Suitable for: Murray 1 in 12-Space or Larger Load Centers
|
Siemens Closure Plate, 3/4 in Nominal, Dimensions: 12.8 X 5.2 X 3.7 in
|
For equipment grounding provision. #14 to 4 AWG, 60/75 deg Celsius, Cu/A1.
|
|
|
|
|
|
|
|
|
|
|
|
|
Breaker box neutral lug is designed for Homeline load centers. It works with number 1 to 1/0 copper and aluminum wire. UL listed and ANSI certified.
|
Used in load centers, CSED devices and NQOD and NF panel boards. Each terminal accepts one #14 - #4 copper wire or one #12 - #4 aluminum wire, two #14 - #12 copper wire or two #12 - #10 aluminum wire. ANSI certified and UL listed.
|
Cutler-Hammer Ground Bar Kit, 10 Terminals, 4.7 in Length, 2.3 in Width, 1/2 in Height
|
|
|
|
|
|
|
|
|
|
|
|
|
Siemens ECLX Ground Bar Kit, 70/100 A, 7 Terminals, (2) 14 to 1/0 AWG Large Opening Copper/Aluminum, (5) 14 to 6 AWG Small Opening Wire, Aluminum/Copper, 2-5/16 in Length, Suitable for: Murray 1 in 12-Space or Larger Load Centers
|
Siemens ECLX Ground Bar Kit, 19 Terminals, (14) 14 to 6 AWG Small Opening, (5) 14 to 1/0 Large Opening Copper/Aluminum Wire, Aluminum/Copper, 5-3/4 in Length, Suitable for: Murray 1 in 12-Space or Larger Load Centers
|
Used in load centers, CSED devices and NQOD and NF panel boards. Each terminal accepts one #14 - #4 copper wire or one #12 - #4 aluminum wire, two #14 - #12 copper wire or two #12 - #10 aluminum wire. ANSI certified and UL listed.
|
|
|
|
|
|
|
|
|
|
|
|
|
EATON Ground Bar Kit, 14 Terminals, 14 to 4 AWG Wire, 5.69 in Length
|
Used in load centers, CSED devices and NQOD and NF panel boards. Each terminal accepts one #14 - #4 copper wire or one #12 - #4 aluminum wire, two #14 - #12 copper wire or two #12 - #10 aluminum wire. ANSI certified and UL listed.
|
For equipment grounding provision. #14 to 4 AWG, 60/75 deg Celsius, Cu/A1.
|
|
|
|
|
|
|
|
|
|
|
|
|
Used in load centers, CSED devices and NQOD and NF panel boards. Each terminal accepts one #14 - #4 copper wire or one #12 - #4 aluminum wire, two #14 - #12 copper wire or two #12 - #10 aluminum wire. ANSI certified and UL listed.
|
For equipment grounding provision. #14 to 4 AWG, 60/75 deg Celsius, Cu/A1.
|
An air conditioning disconnect (ACD) is a disconnect located between the load center and the air conditioner. Eaton's ACD provides an installer or repair personnel with a visible disconnecting means when performing maintenance.
|
|
|
|
|
|
|
|
|
|
|
|
|
Single phase, 2 pole, 2 wire, 240 V, rated 10 HP, steel enclosure. All lugs positioned for bottom entry and exit wiring. Easy mounting for quick installation. Pullout head can be replaced in off position. 10,000 AIR. 12 - 3 AWG al, 14 - 3 kcmil cu lug wire range. 5-5/32 in x 7-5/16 in x 2-7/32 in. UL listed.
|
An air conditioning disconnect (ACD) is a disconnect located between the load center and the air conditioner. Eaton's ACD provides an installer or repair personnel with a visible disconnecting means when performing maintenance.
|
An air conditioning disconnect (ACD) is a disconnect located between the load center and the air conditioner. Eaton's ACD provides an installer or repair personnel with a visible disconnecting means when performing maintenance.
|
|