Home > ELECTRICAL > ROUGH ELECTRICAL > FUSES & BREAKERS > CIRCUIT BREAKERS - DBL POLE
Sort By:
1 2 3 4
GE THQL2120 Type THQL Q-Line Standard Circuit Breaker GE THQL2130 Type THQL Q-Line Standard Circuit Breaker GE THQL2140 Type THQL Q-Line Standard Circuit Breaker
Copper-to-copper connections, calibrated for optimum trip performance, heat-resistant thermoset cases and covers, cemented calibration screw. May be used, when marked to accept, with American Switch, Arrow Hart, Bryant, General Switch, GTE, Sylvania, most ITE, Murray, Westinghouse Type BR, Challenger, Crouse-Hinds. 15 to 30 A 14-8 cu or 12-8 al AWG wire, 35 to 60 A 8-3 cu or 8-2 al AWG wire, 70 to 100 A 6-1/0 cu or 4-1/0 al AWG wire. UL Listed, HACR rated. 120/240 V, 10,000 Air. 1 in per pole (2 in total). Copper-to-copper connections, calibrated for optimum trip performance, heat-resistant thermoset cases and covers, cemented calibration screw. May be used, when marked to accept, with American Switch, Arrow Hart, Bryant, General Switch, GTE, Sylvania, most ITE, Murray, Westinghouse Type BR, Challenger, Crouse-Hinds. 15 to 30 A 14-8 cu or 12-8 al AWG wire, 35 to 60 A 8-3 cu or 8-2 al AWG wire, 70 to 100 A 6-1/0 cu or 4-1/0 al AWG wire. UL Listed, HACR rated. 120/240 V, 10,000 Air. 1 in per pole (2 in total). Copper-to-copper connections, calibrated for optimum trip performance, heat-resistant thermoset cases and covers, cemented calibration screw. May be used, when marked to accept, with American Switch, Arrow Hart, Bryant, General Switch, GTE, Sylvania, most ITE, Murray, Westinghouse Type BR, Challenger, Crouse-Hinds. 15 to 30 A 14-8 cu or 12-8 al AWG wire, 35 to 60 A 8-3 cu or 8-2 al AWG wire, 70 to 100 A 6-1/0 cu or 4-1/0 al AWG wire. UL Listed, HACR rated. 120/240 V, 10,000 Air. 1 in per pole (2 in total).
GE THQL2150 Type THQL Q-Line Standard Circuit Breaker GE THQL2160 Type THQL Q-Line Standard Circuit Breaker CIRCUIT BREAKR THQP 2P 1IN 50A
Copper-to-copper connections, calibrated for optimum trip performance, heat-resistant thermoset cases and covers, cemented calibration screw. May be used, when marked to accept, with American Switch, Arrow Hart, Bryant, General Switch, GTE, Sylvania, most ITE, Murray, Westinghouse Type BR, Challenger, Crouse-Hinds. 15 to 30 A 14-8 cu or 12-8 al AWG wire, 35 to 60 A 8-3 cu or 8-2 al AWG wire, 70 to 100 A 6-1/0 cu or 4-1/0 al AWG wire. UL Listed, HACR rated. 120/240 V, 10,000 Air. 1 in per pole (2 in total). Copper-to-copper connections, calibrated for optimum trip performance, heat-resistant thermoset cases and covers, cemented calibration screw. May be used, when marked to accept, with American Switch, Arrow Hart, Bryant, General Switch, GTE, Sylvania, most ITE, Murray, Westinghouse Type BR, Challenger, Crouse-Hinds. 15 to 30 A 14-8 cu or 12-8 al AWG wire, 35 to 60 A 8-3 cu or 8-2 al AWG wire, 70 to 100 A 6-1/0 cu or 4-1/0 al AWG wire. UL Listed, HACR rated. 120/240 V, 10,000 Air. 1 in per pole (2 in total). Copper-to-copper connections, calibrated for optimum trip performance, heat-resistant thermoset cases and covers, cemented calibration screw. Nearly identical to Type THQL with the same design and performance, yet only taking up 1/2 the space. 1/2 in per pole. UL listed, HACR rated. 15 to 25 A 14 to 8 cu or 12 to 8 al AWG wire, 30 to 50 A 8 to 4 cu or 8 to 2 al AWG wire. 3-9/32 in H x 1/2 in W x 2-3/8 in D. 120/240 V, 10,000 AIR.
BREAKER CIRCUIT 2POLE 1IN 40A BREAKER CIRCUIT 2POLE 1IN 30A GE THQP220 Type THQP Q-Line Miniature Circuit Breaker
Copper-to-copper connections, calibrated for optimum trip performance, heat-resistant thermoset cases and covers, cemented calibration screw. Nearly identical to Type THQL with the same design and performance, yet only taking up 1/2 the space. 1/2 in per pole. UL listed, HACR rated. 15 to 25 A 14 to 8 cu or 12 to 8 al AWG wire, 30 to 50 A 8 to 4 cu or 8 to 2 al AWG wire. 3-9/32 in H x 1/2 in W x 2-3/8 in D. 120/240 V, 10,000 AIR. Copper-to-copper connections, calibrated for optimum trip performance, heat-resistant thermoset cases and covers, cemented calibration screw. Nearly identical to Type THQL with the same design and performance, yet only taking up 1/2 the space. 1/2 in per pole. UL listed, HACR rated. 15 to 25 A 14 to 8 cu or 12 to 8 al AWG wire, 30 to 50 A 8 to 4 cu or 8 to 2 al AWG wire. 3-9/32 in H x 1/2 in W x 2-3/8 in D. 120/240 V, 10,000 AIR. Copper-to-copper connections, calibrated for optimum trip performance, heat-resistant thermoset cases and covers, cemented calibration screw. Nearly identical to Type THQL with the same design and performance, yet only taking up 1/2 the space. 1/2 in per pole. UL listed, HACR rated. 15 to 25 A 14 to 8 cu or 12 to 8 al AWG wire, 30 to 50 A 8 to 4 cu or 8 to 2 al AWG wire. 3-9/32 in H x 1/2 in W x 2-3/8 in D. 120/240 V, 10,000 AIR.
CIRCUIT BREAKER HOM 2P 1IN 15A CIRCUIT BREAKER HOM 2P 1IN 30A CIRCUIT BREAKER HOM 2P 1IN 40A
Double pole 2" circuit breaker features 10,000 AIR and 120/240 VAC. Thermal-magnetic tripping mechanism for overload and short-circuit protection of electrical system. Accepts aluminum or copper conductors. CSA approved to only install in Canadian HomeLine loadcentres. Double pole 2" circuit breaker features 10,000 AIR and 120/240 VAC. Thermal-magnetic tripping mechanism for overload and short-circuit protection of electrical system. Accepts aluminum or copper conductors. CSA approved to only install in Canadian HomeLine loadcentres. Double pole 2" circuit breaker features 10,000 AIR and 120/240 VAC. Thermal-magnetic tripping mechanism for overload and short-circuit protection of electrical system. Accepts aluminum or copper conductors. CSA approved to only install in Canadian HomeLine loadcentres.
CIRCUIT BREAKER HOM 2P 1IN 50A CIRCUIT BREAKER HOM 2P 1IN 60A CIRCUIT BREAKER HOM 2P 1IN 20A
Double pole 2" circuit breaker features 10,000 AIR and 120/240 VAC. Thermal-magnetic tripping mechanism for overload and short-circuit protection of electrical system. Accepts aluminum or copper conductors. CSA approved to only install in Canadian HomeLine loadcentres. Double pole 2" circuit breaker features 10,000 AIR and 120/240 VAC. Thermal-magnetic tripping mechanism for overload and short-circuit protection of electrical system. Accepts aluminum or copper conductors. CSA approved to only install in Canadian HomeLine loadcentres. Double pole 2" circuit breaker features 10,000 AIR and 120/240 VAC. Thermal-magnetic tripping mechanism for overload and short-circuit protection of electrical system. Accepts aluminum or copper conductors. CSA approved to only install in Canadian HomeLine loadcentres.
HomeLine HOM250C Miniature Standard Circuit Breaker HomeLine HOM260C Miniature Standard Circuit Breaker MES Q220 Standard Miniature Circuit Breaker
Homeline miniature circuit breakers are engineered and designed for fast installation and great circuit protection. Homeline circuit breakers are designed to plug into Homeline load centers to provide circuit protection. This circuit breaker provides standard circuit protection and is HACR rated. This single pole circuit breaker with plug-in mounting is rated 50 A at 120/240 VAC. HOM breakers provide 10 kA breaking capacity. The electrical connection is a clamp terminal that will accept two wires. The clamp terminal will accept a wire range of 14 AWG to 8 AWG copper or aluminum wire. HOM Homeline miniature circuit breakers are UL Listed. Circuit breaker is consumer packaged. Homeline miniature circuit breakers are engineered and designed for fast installation and great circuit protection. Homeline circuit breakers are designed to plug into Homeline load centers to provide circuit protection. This circuit breaker provides standard circuit protection and is HACR rated. This single pole circuit breaker with plug-in mounting is rated 60 A at 120/240 VAC. HOM breakers provide 10 kA breaking capacity. The electrical connection is a clamp terminal that will accept two wires. The clamp terminal will accept a wire range of 14 AWG to 8 AWG copper or aluminum wire. HOM Homeline miniature circuit breakers are UL Listed. Circuit breaker is consumer packaged. Molded case with non-interchangeable trip. Will replace American Switch, Westinghouse Type BR, Bryant, Challenger, Sylvania, Crouse-Hinds, Murray, Frank Adams, General Electric (full size only), General Switch, I-T-E, Gould, Montgomery Ward and Sears. UL Listed. HACR rated. 120/240 VAC, 10,000 AIR. 1 in per pole (2 in total).
MES Q230 Standard Miniature Circuit Breaker MES Q240 Standard Miniature Circuit Breaker MES Q250 Standard Miniature Circuit Breaker
Molded case with non-interchangeable trip. Will replace American Switch, Westinghouse Type BR, Bryant, Challenger, Sylvania, Crouse-Hinds, Murray, Frank Adams, General Electric (full size only), General Switch, I-T-E, Gould, Montgomery Ward and Sears. UL Listed. HACR rated. 120/240 VAC, 10,000 AIR. 1 in per pole (2 in total). Molded case with non-interchangeable trip. Will replace American Switch, Westinghouse Type BR, Bryant, Challenger, Sylvania, Crouse-Hinds, Murray, Frank Adams, General Electric (full size only), General Switch, I-T-E, Gould, Montgomery Ward and Sears. UL Listed. HACR rated. 120/240 VAC, 10,000 AIR. 1 in per pole (2 in total). Molded case with non-interchangeable trip. Will replace American Switch, Westinghouse Type BR, Bryant, Challenger, Sylvania, Crouse-Hinds, Murray, Frank Adams, General Electric (full size only), General Switch, I-T-E, Gould, Montgomery Ward and Sears. UL Listed. HACR rated. 120/240 VAC, 10,000 AIR. 1 in per pole (2 in total).
MES Q260 Standard Miniature Circuit Breaker BREAKER CIRC 2-POLE 240V 15A  Eaton BR215 Type BR Miniature Circuit Breaker
Molded case with non-interchangeable trip. Will replace American Switch, Westinghouse Type BR, Bryant, Challenger, Sylvania, Crouse-Hinds, Murray, Frank Adams, General Electric (full size only), General Switch, I-T-E, Gould, Montgomery Ward and Sears. UL Listed. HACR rated. 120/240 VAC, 10,000 AIR. 1 in per pole (2 in total). Siemens Circuit Breaker, 120/240 V, 15 A, Operating Frequency: 50/60 Hz, Number of Phases: 1, Number of Poles: 2, Interrupt Rating: 10 kA, Frame Type: QP, Frame Size: 2 in, Actuator Type: Magnetic, Thermal, Contact Configuration: DPST, Wire Size: 14 to 6 AWG, Terminal Type: Lug, Plug Mounting, Dimensions: 3 in L x 3 in W x 2 in H, Operating Temperature: 40 deg C Cutler-Hammer Circuit Breaker, Mini, Type BR, 120/240 V, 15 A, Operating Frequency: 50/60 Hz, Number of Phases: 1, Number of Poles: 2, Interrupt Rating: 42 kA, Actuator Type: Quick-Break, Quick-Make, Trip Type: Common, Wire Size: 14 to 4 AWG, Number of Spaces: 2, Plug Mounting, Dimensions: 2.92 in L x 1.96 in W x 2.92 in H, Operating Temperature: 60 to 75 deg C, Suitable for: Type BR Load Centers
CIRCUIT BRKR TBA 2P2SPC 20/20A CIRCUIT BRKR TBA 2P2SPC 30/30A BREAKER BR 2P 50 AMP 10KA
Interchangeable, will replace: Bryant, Challenger and Westinghouse. Type BR. 120/240 V. 10 kAIC, 10,000 AIR. 2 spaces, 2 in per breaker. Interchangeable, will replace: Bryant, Challenger and Westinghouse. Type BR. 120/240 V. 10 kAIC, 10,000 AIR. 2 spaces, 2 in per breaker. Interchangeable, will replace: Bryant, Challenger and Westinghouse. Type BR. 120/240 V. 10 kAIC, 10,000 AIR. 2 spaces, 2 in per breaker.
Eaton BR225 Type BR Miniature Circuit Breaker CIRCUIT BRKR TBA 2P2SPC 40/40A Eaton BR260 Type BR Miniature Circuit Breaker
Interchangeable, will replace: Bryant, Challenger and Westinghouse. Type BR. 120/240 V. 10 kAIC, 10,000 AIR. 2 spaces, 2 in per breaker. Interchangeable, will replace: Bryant, Challenger and Westinghouse. Type BR. 120/240 V. 10 kAIC, 10,000 AIR. 2 spaces, 2 in per breaker. Cutler-Hammer Circuit Breaker, Type BR, 120/240 V, 60 A, Operating Frequency: 50/60 Hz, Number of Phases: 1, Number of Poles: 2, Interrupt Rating: 42 kA, Wire Size: 8 to 1/0 AWG, Plug Mounting, Dimensions: 2.93 in L x 1.96 in W x 2.92 in H, Operating Temperature: 60 to 75 deg C
   
 
1 2 3 4