Home > ELECTRICAL > ROUGH ELECTRICAL > PANEL BOXES > DISCONNECT BOXES
Sort By:
1
Eaton DPU222RP Type ACD Non-Fusible Pullout Disconnect Switch Cutler-Hammer DPF221RP AC Disconnect Switches Square D QO200TRCP Molded Non-Fusible Disconnect Switch
An air conditioning disconnect (ACD) is a disconnect located between the load center and the air conditioner. Eaton's ACD provides an installer or repair personnel with a visible disconnecting means when performing maintenance. An air conditioning disconnect (ACD) is a disconnect located between the load center and the air conditioner. Eaton's ACD provides an installer or repair personnel with a visible disconnecting means when performing maintenance. Air conditioning disconnects from Schneider Electric are Underwriters Laboratories? (UL?) Listed NEMA Type 3R rainproof. They are designed to meet all current National Electrical Code? (NEC?) requirements for a disconnecting means on residential and commercial air conditioning installations, as well as other single-phase applications, such as swimming pools and pump houses.
Cutler-Hammer DPF222RP AC Disconnect Switches Cutler-Hammer AC222URNMP-A2 AC Disconnect Switches Siemens Energy WN2060U AC Disconnect Switches
An air conditioning disconnect (ACD) is a disconnect located between the load center and the air conditioner. Eaton's ACD provides an installer or repair personnel with a visible disconnecting means when performing maintenance. Single phase, 2 pole, 2 wire, 240 VAC. Rated 3 hp at 120 V, 10 hp at 240 V. For top and bottom entry and exit, with provision for type H conduit hub. Heavy-duty, high strength, rugged polymer enclosure with UV-resistant features. Swing-up cover remains in place when in open position, protective shield can be removed for access to fuses. No GB4 ground bar and No 360-011-24 pullout head replacement sold separately. #14-2 AWG wire range. 5 in x 8-5/8 in x 3-1/2 in. UL listed file No E5239. Single phase, 2 pole, 2 wire, 240 V, rated 10 HP, steel enclosure. All lugs positioned for bottom entry and exit wiring. Easy mounting for quick installation. Pullout head can be replaced in off position. 10,000 AIR. 12 - 3 AWG al, 14 - 3 kcmil cu lug wire range. 5-5/32 in x 7-5/16 in x 2-7/32 in. UL listed.
SWITCH AC DISCONNECT 60A A    GE Electrical TF60RCP AC Disconnect Switches GE Electrical TFN60RCP AC Disconnect Switches
For use as service disconnect. Outdoor enclosed pullout switch. Type 3R, 240 VAC, single phase. Removable door. cULus Listed. Steel enclosure. 2-pole, 3-wire, 120/240 VAC, rated 10 hp. Uses cartridge fuses. For central air conditioner. Designed to comply with code requirements for disconnecting means within sight of central air conditioners and heat pumps. Removable closing cap not included. Equipment ground. 14-3 AWG lug wire range. 6-1/2 x 9 x 3-1/4 in. UL869 service equipment, UL listed. Steel enclosure. 2-pole, 3-wire, 240 VAC, rated 10 hp. For central air conditioner. Removable closing cap not included. Equipment ground. 14-3 AWG lug wire range. 4-3/4 x 7-1/2 x 2 in. UL1429 enclosure pullout switch, UL listed.
SWITCH AC DISCONNECT 30A A    Cutler-Hammer ACD221RNMP AC Disconnect Switches Eaton DPB222RP Type ACD Molded Non-Automatic Breaker Disconnect Switch
For use as service disconnect. Outdoor enclosed pullout switch. Type 3R, 240 VAC, single phase. Removable door. cULus Listed. Single phase, 2 pole, 2 wire, 240 VAC, non-metallic enclosure. Rated 1-1/2 hp at 120 V, 3 hp at 240 V with time delay fuses (uses class H cartridge fuses, not included). For top and bottom entry and exit, with provision for type H conduit hub. Heavy-duty, high strength, rugged polymer enclosure with UV-resistant features. 10,000 A RMS symmetrical interrupting rating. Suitable for use as service entrance equipment with ground bar. No GB4 ground bar and No 360-011-24 pullout head replacement sold separately. #14-2 AWG wire range. 5 in x 8.63 in x 3-1/2 in. UL listed file No E5239. Air conditioning disconnect, molded case switch looks like a circuit breaker but operates like an ordinary household light switch. 60 A, 2-pole, 240 VAC. Metallic, galvanized steel enclosure, NEMA 3R, rainproof. Packaged for retail sale. Wire size range Cu or Al at 60 or 70 deg C, #14-3. UL listed, CSA approved.
   
 
1